Text Survey to Josh
Print / Save PDF
Clear All
+ Expand All
− Collapse All
1. The Conversation
“Before I start measuring — what made you decide to look at a new system?
Any rooms that never get comfortable? And is there a budget you’re trying to stay
inside, so I can quote you the right options?”
Ask why they want the install — comfort, failure, age, selling the house?
Ask about problem rooms — hot/cold spots, airflow, noise complaints.
Ask the budget question — never skip it. It decides which options we quote.
Ask if they want specific equipment — brand, quiet, high-efficiency, smart stat.
Ask their timeline — this week, this season, just pricing it out?
On a budget? (range if shared)
Specific equipment requests
Timeline
Why they're buying / main complaint
Financing note: always mention we have options for tight budgets — monthly plans and financing. Nobody gets embarrassed about price at JL.
2. Existing Equipment
Photo of furnace/air handler data plate (make, model, serial).
Note furnace orientation — upflow / downflow / horizontal.
Check venting — 80% (metal flue) or high-efficiency 90%+ (PVC)?
If 80%: check flue condition, water heater shares the flue? (orphaned WH = liner talk)
Note filter size and location.
Note existing AC / cooler / coil — what gets removed or stays?
Furnace make / model / age
Orientation
Upflow
Downflow
Horizontal
Venting
80% — metal flue
High-eff 90%+ — PVC
Electric / no flue
Filter size
Equipment being removed
Equipment location
3. Measurements — Coil & Plenum
Measure, don't eyeball. Coil that doesn't fit the plenum = a lost day and an unhappy customer.
Measure furnace/air handler cabinet width & depth.
Measure height available above furnace for coil (to first duct fitting/obstruction).
Measure supply plenum width × depth.
Measure return drop / return duct size, count return locations.
Measure door/stair/access clearance for getting equipment in and out.
Cabinet width × depth
Height above furnace for coil
Supply plenum W × D
Return size / count
4. Condensate & Drains
Is there a floor drain near the equipment? How far?
Can condensate route to an outside drain by gravity?
If no gravity path: condensate pump needed — where does it discharge?
Attic/finished space above living area: secondary drain pan + float switch required.
Floor drain?
Yes — close
Yes — far (measure run)
No — pump needed
No — gravity to outside works
Drain route notes
5. Line Set Route
Walk the line set path from coil to outdoor unit location — is it possible?
Estimate line set length (ft) and count wall penetrations.
Existing line set present? Right size / reusable or replace?
Visible runs: line set cover needed for a clean professional look?
Line set possible to outside?
Yes — clean path
Yes — tight / extra labor
Problem — see notes
Est. length + route notes
6. Electrical
Check the panel BEFORE quoting. No room for a 2-pole breaker changes the price of the job.
Photo of the panel — cover on AND cover off if safe.
Panel brand, main breaker amps, open spaces for new 2-pole circuit.
Overall condition — burnt lugs, double taps, rust, recalled panel (Zinsco / FPE)?
Measure distance panel → outdoor unit location (wire run).
Disconnect + whip present or needed at outdoor location?
Thermostat wire — how many conductors? C-wire available for new stat?
Panel brand / main amps
Room for new circuit?
Yes — open spaces
Tight — tandem/rework needed
No — panel work required
Panel condition
Wire run distance / notes
7. Outdoor Unit Location
Pick the pad spot — level ground, solid base, good service access.
Clearances — walls, fence, gas meter, dryer vent, property line.
Noise check — distance to bedroom windows, patio, neighbor's window.
Photo of the spot from a few feet back.
Outdoor location notes
8. House & Sizing
Square footage + levels (ask or look up).
Windows — old single-pane or newer? Big west-facing glass?
Insulation impression — attic depth, house age.
Sq ft / levels / year built
Sizing notes
9. Photo Pass
Photos answer the questions you forgot to ask. Take them all — 2 minutes now saves a return trip.
Furnace + data plate
Coil/plenum space above furnace
Electrical panel (cover on + off)
Line set path + wall penetration spot
Outdoor unit location
Attic access + hanging area (if attic job)
Thermostat + wire count
10. Wrap-Up With Customer
“I’ve got everything I need — measurements, electrical, and the routing all check out.
We’ll put together your options and get you a written estimate shortly.
Nothing happens until you approve it, and there’s no pressure either way.”
Tell them when to expect the estimate.
Confirm best phone/email for sending it.
Tap "Text Survey to Josh" at the top — the estimate gets built from this card.
Anything else Josh should know
JL Heating & Air — Install estimate survey. Filled out fully = estimate built with zero follow-up questions.